菜单

设备技术

压力测量是的
燃气检测是的
个人防护是的
漏水检测是的
线路和瓶盖定位是的
LTE模块是的
蓝牙是的
爆炸保护是的
H2准备100%是的
H2准备高达30%是的
红外线是的
每页条目
1 - 20 / 84
OLLI Tracer Gas
新的
OLLI Tracer GasPortable gas leak detector with integrated pump, bluetooth and Li-Ion battery for leak detection using forming gas (5% H2 in 95% N2). Extremely resistant 2K plastic housing Operating time > 35 hours (depending on ambient conditions, without lighting) Pump flow approx. 20 l/h Dimensions (LxWxH): 170 x 80 x 43 mm, Weight: approx. 380 g
HUNTER Tracer Gas
新的
HUNTER Tracer GasGas detection device for easily locating even the smallest leaks in pipes using forming gas (5 Vol.% H2 in N2) - highly sensitive hydrogen sensor with a resolution of 0,1 ppm H2 - extremely fast reaction to the smallest traces of hydrogen - second sensor for pinpointing in probe holes - integrated pump with high power for flow and for negative pressure Operation time: > 10 hours without lighting Measuring ranges: 0 to 1000 ppm H2 0 to 5 Vol.% H2 in N2 dimensions: approx. 200 x 100 x 87 mm weight: approx. 1100 g
GasTest delta3
GasTest delta3GasTest delta3 Measurement instrument for indoor gas installation Pressure and leak measurement instrument in accordance with DVGW G 600, G 5952. Operating time varies depending on the way of usage and power consumption (e.g. serviceability in accordance with G 5952 approx. 50 tests) Serviceability test (measurement range 0 - 10 l/h) Gastightness test (measurement range 0 - 300 hPa) Load test (measurement range 0 - 1000 hPa) Serviceability test in accordance with G 5952 and with Esders express procedure Automatic and manual test on regulators (optional) Test on service lines in accordance with DVGW G 459-1 using G 469 B3 procedure (optional) - Automatic regulator test including storage of outlet pressure (flowing gas and standing gas), SSV overpressure cut-off and gastight closure - Manual regulator test including storage of outlet pressure (flowing gas and standing gas), SRV threshold pressure and gastight closure, SSV overpressure and underpressure cut-off and gastight closure - Gas detection via external, digital handheld sensor possible - Pressure test up to 25 bar via external sensors possible - Data storage, infrared and bluetooth interface - Display with touch function to enter address data, project number, meter and/or regulator number, etc. Dimensions: 192 x 100 x 87 mm Weight: approx. 1160 g
smart memo
smart memoElectronic pressure test case for pressure tests with connection possibility of up to 5 external pressure or temperature sensors. - the test procedures are menu-guided and can be carried out with simple Data entry dialog - a freely programmable pressure test is included - optional test sequences for gas and water tightness tests e.g. according to DVGW, ÖVGW, EWE, Avacon, WEVG. - a subsequent addition of test sequences is possible easily - large, illuminated display, even in direct sunlight easy to read - data entry and signature via touch display and foil keys - stylus for the touch display included - data memory for hundreds of measurements, depending on test sequence - communication via Bluetooth for updates and data transmission (costs may apply for data transmission to the cloud) - LTE / GPS module (optional) - robust case (IP 67) - operating time approx. 200 hours, extension with power supply possible from outside Dimensions: 220 x 90 x 168 mm Weight: approx. 1450 g
OLLI
OLLIGas measurement & warning device with certified measuring function for explosion protection. This variant of the OLLI is included in the BG RCI list of function-tested gas detectors (see article 280000 for the variant without certification). Explosion-proof & compact diffusion hand-held measuring device. It can be used for up to 5 combustible and toxic gases as well as oxygen and comes in an extremely rugged 2C synthetic housing with rechargeable and explosion-proof Li-ion battery pack. Charging the battery in potentially explosive atmospheres is not permitted! Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based on customer requirements. The device can optionally be equipped with a pump and pressure sensor. Operating time > 50 hours (depending on type & number of installed sensors and ambient conditions, w/o illumination) Measurement ranges are subject to sensor assembly Dimensions: 136 x 78 x 43 mm Weight: approx. 350 g Explosion-proof measurement instrument (active & passive) Measuring function certified for methane (CH4), propane (C3H8), oxygen (O2), carbon monoxide (CO), carbon dioxide (CO2), hydrogen sulfide (H2S) according to the following standards: EN 60079-29-1 EN 50104 EN 45544-1 EN 45544-3 ATEX Marking: II 2G Ex ib db IIB T4 Gb (EU-)type examination certificates: BVS 17 ATEX E 043 X TÜV 21 ATEX 8596 X TÜV 21 PTG 7001 X 968/FSP 1940.05/21 Kennzeichnung IECEx: Ex ib db IIB T4 Gb IECEx BVS 21.0085X Temperature range: -20°C <= Ta <= +50°C
Laser HUNTER Gas detection & Gas measurement device
Laser HUNTER
Gas detection & Gas measurement deviceHighly sensitive and selective gas detection & gas measurement device with laser technology for the inspection of underground gas pipes using suitable probes (e. g. carpet probe). The device can also be used for the vehicle-based pipeline inspection. With built-in diaphragm pump, Bluetooth module and rechargeable Li-Ion battery. One out of two different laser modules can be assembled: - single laser module for methane or - dual laser module for methane & ethane Moreover, the device can be equipped with additional sensors to enable further applications. The following applications are possible: - Inspection of underground pipes - Inspection of accessible pipes in buildings - Inspection of accessible pipes on plants, etc. - Inspection of ground soil for pinpointing (optional) - Purging of gas pipelines (optional, only in combination with pinpointing) - Gas analysis (with dual laser module) Operating time up to 10 hours Measurement range depending on built-in sensors Dimensions (LxWxH): 143 x 240 x 85 mm Weight: 2.1 kg Temperature ranges: 0 °C to 40 °C (dual laser module) -10 °C to 50 °C (single laser module)
HUNTER H2
HUNTER H2Gas detection device for easily locating even the smallest leaks in water and heating systems - special, highly sensitive hydrogen sensor with a resolution of 0,1 ppm H2 - extremely fast reaction to the smallest traces of hydrogen - second sensor for pinpoint localisation in probe holes - integrated pump with high power for flow and for negative pressure Operation time: > 10 hours without lighting Measuring ranges: 0 to 1000 ppm H2 0 to 5 Vol.% H2 in N2 dimensions: 200 x 100 x 87 mm weight: approx. 1100 g temperature range: -10°C to +50°C
HUNTER Gas detection & gas measurement device
HUNTER
Gas detection & gas measurement deviceGas detection & gas measurement device for the inspection of underground gas pipes using suitable probes (e. g. carpet probe). With built-in diaphragm pump, Bluetooth module and rechargeable Li-Ion battery. The device can be equipped with additional sensors to enable further applications. The following applications are possible: - Inspection of underground pipes - Inspection of accessible pipes in buildings - Inspection of accessible pipes on plants, etc. - Inspection of ground soil for pinpointing (optional) - Purging of gas pipes (optional, only in combination with pinpointing) Operating approx. 10 hours Measurement ranges depending on built-in sensors Dimensions (LxWxH): 100 x 195 x 86 mm Weight: 1.1 kg Temperature range: -10°C to 50°C
GOLIATH RN with Ethane analysis
GOLIATH RN with Ethane analysisGOLIATH RN with Ethane analysis methane and toxic gases Detect - Measure - Analyse Rugged, explosion proofed measurement instrument with internal membranpump and reachargeable NiMH- battery. Operating time: depending on application and backlight Application in accordance with DVGW G 465-4: - Enclosed space testing - Above ground inspection - Building inspection - Bar hole testing - Purging gas purity - Ethane analysis Measurement ranges: - methane ppm, Vol.% - carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2 - oxygen 0 - 25 Vol.% O2 (optional) - carbon monoxide 0 - 500 ppm CO (optional) Dimensions: 200 x 100 x 87 mm Weight: approx. 1250 g Explosion proofed instrument: Sign: II 2G Ex ib d IIB T3/T4 Gb BVS 09 ATEX E 079 X Temperature range: -10°C <= Ta <= +40°C
Druktest max
Druktest maxDruktest max test case for tightness measurements with internal pressure sensor with an accuracy of 0.25 %, resolution up to 0.1 mbar, measuring range up to 1.6 bar. - menu-guided test procedures: - G-07 and G-12 included - G-22 to MOP 100 mbar (optional) - Pressure test free (optional) - large, illuminated display, easy to read even in direct sunlight - data input and signature via touch display - internal pump and pressure release valve for automatic test pressure generation - data memory for hundreds of measurements, depending on test procedure - communication via Bluetooth - LTE / GPS module (optional) - robust case (IP 67) - operating time several days, depending on test procedure - dimensions: approx. 263 x 205 x 110 mm, weight: approx. 2300 g
OLLI
OLLIGas measurement & warning device without certified measuring function for explosion protection. This variant of the OLLI is NOT on the BG RCI list of function-tested gas detectors (see article 280010). Explosion-proof & compact handheld gas measurement instrument as diffusion device. It can be used for up to 5 combustible and toxic gases as well as oxygen and comes in an extremely rugged 2C synthetic housing with 3 alkaline manganese primary cells. Up to 3 gas sensors can be installed (Ex/Ox/Tox). Assembly is based on customer requirements. The device can be optionally equipped with a Li-ion battery pack, pump and pressure sensor. Operating time > 50 hours (depending on type & number of installed sensors and ambient conditions, w/o illumination) Measurement ranges are subject to sensor assembly Dimensions: 136 x 78 x 43 mm Weight: approx. 350 g Explosion-proof measurement instrument, ATEX marking: II 2G Ex ib db IIB T4 Gb BVS 17 ATEX E 043 X Marking (IECEx): Ex ib db IIB T4 Gb IECEx BVS 21.0085X Temperature range: -20°C <= Ta <= +50°C
ELLI Esders Laser Leak Indicator Set
ELLI Esders Laser Leak Indicator SetELLI Esders Laser Leak Indicator Set ELLI is an innovative, portable laser methane (CH4) measuring instrument that can be easily monitor difficult or impossible to reach areas and hazardous areas from a distance. Technical data: Calibration gas: methane (CH4) Display: color LCD touch screen Scanning range: 30 m standard, 50 m under good reflection conditions Reaction time: 0.1 seconds Detection method: tuneable diode laser absorption spectroscopy (TDLAS) Weight: approx. 1,6 kg Dimensions: approx. 237 x 167 x 74 mm Measuring range: 0 ... 50.000 ppm x m Temperature range: -17°C to 50°C Humidity: 5 to 90% rel. humidity Protection class: IP54 Operating time: 8 hours per charge (6 hours charging time) Power supply: rechargeable Li-ion battery Connections: USB, earphone, GPS, bluetooth Scope of delivery: earphones, carrying belt, rugged carrying case, charger
GOLIATH Allround without Ethane analysis
GOLIATH Allround without Ethane analysismethane/propane and toxic gases Detect - Warn - Measure Rugged, explosion proofed measurement instrument with internal membranpump and reachargeable NiMH- battery. operating time: depending on application and backlight Application in accordance with DVGW G 465-4: - Enclosed space testing - Above ground inspection - Confined space entry - Building inspection - Bar hole testing - Purging gas purity Measurement ranges: - methane ppm, LEL, Vol.% - carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2 - propane ppm, LEL, Vol.% (optional) - oxygen 0 - 25 Vol.% O2 (optional) - carbon monoxide 0 - 500 ppm CO (optional) - hydrogen sulphide 0 - 100 ppm H2S (optional) - pressure measurement 0 - 2.000 hPa (optional) - flow speed measurement (optional) Dimensions: 200 x 100 x 87 mm Weight: approx. 1250 g Explosion proofed instrument: Sign: II 2G Ex ib d IIB T3/T4 Gb BVS 09 ATEX E 079 X Temperature range: -10°C <= Ta <= +40°C
Opgal EyeCGas Multi
Opgal EyeCGas MultiKit includes: - EyeCGas Multi Camera - Multi Spectral Filters (VOC und CO2) - 2x EyeCGas Battery - EyeCGas Singel Battery Charger - EyeCGas Multi Carrying Case - EyeCGas Glare Shield - EyeCGas Shoulder Strap - EyeCGas Lens Pen Cleaner
GOLIATH Biogas B
GOLIATH Biogas B Rugged, explosion proofed gas measurement instrument with internal membrane pump and reachargeable NiMH-battery for the specific use in biogas, landfill and sewage gas. Operating time > 8 to > 12 hours depending on application (without backlight) Measurement ranges: - methane 0 - 100 Vol.% CH4 - carbon dioxide 0 - 100 Vol.% CO2 - oxygen 0 - 25 Vol.% O2 (optional) - hydrogen sulphide 0 - 100 ppm H2S (optional) - hydrogen sulphide 0 - 1000 ppm H2S (optional) - hydrogen sulphide 0 - 2000 ppm H2S (optional) Dimensions: 200 x 100 x 87 mm Weight: approx. 1200 g Explosion proofed instrument: Sign: ll 2G Ex ib d llB T3/T4 Gb BVS 09 ATEX E 079 X Temperature range: -10°C < Ta < +40°C
GOLIATH Allround with Ethane analysis
GOLIATH Allround with Ethane analysismethane and toxic gases Detect - Warn - Measure - Analyse Rugged, explosion proofed measurement instrument with internal membranpump and reachargeable NiMH- battery. Operating time: depending on application and backlight Application in accordance with DVGW G 465-4: - Enclosed space testing - Above ground inspection - Confined space entry - Building inspection - Bar hole testing - Purging gas purity - Ethane analysis Measurement ranges: - methane ppm, LEL, Vol.% - carbon dioxide 0 - 5 Vol.% / 0 - 100 Vol.% CO2 - oxygen 0 - 25 Vol.% O2 (optional) - carbon monoxide 0 - 500 ppm CO (optional) - hydrogen sulphide 0 - 100 ppm H2S (optional) - pressure measurement 0 - 2.000 hPa (optional) Dimensions: 200 x 100 x 87 mm Weight: approx. 1250 g Explosion proofed instrument: Sign: II 2G Ex ib d IIB T3/T4 Gb BVS 09 ATEX E 079 X Temperature range: -10°C <= Ta <= +40°C
Thermal printer IR 58 mm P3 without power supply
Thermal printer IR 58 mm P3 without power supplyThermal printer with infrared and bluetooth interface. - paper width: 58 mm - powered by rechargeable battery The power supply 230 V (item number: 202002) can be used for charging the thermal printer.
DruckLogger 4 Water
DruckLogger 4 WaterPressure measuring device for water pipeline networks. Measuring range up to 25 bar. Accuracy better than 0,1% from final value. Pressure side with DIN underground hydrant screw connection and ¼ internal thread. Cap with magnet for operating the logger.
Single Gas CO
Single Gas CORobust and reliable CO detector with a limited operating time after activation of up to 2 years. The single gas can be checked daily (bump test) and be calibrated and adjusted by means of test gas and the corresponding infrared communication module integrated event memory. The IR interface allows changes of the alar thresholds and reading of the event memory by means of the IR communication module and PC software ATEX II 1G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4
VibraGAS EX - rechargeable battery
VibraGAS EX - rechargeable batteryVibraGAS EX HMG2 - rechargeable battery Gas leak detector Small, rugged aluminium handheld gas leak detector with remote sensor on the swan neck and lighted display. Display of gas traces by audible, visual and vibrating alarm. measurement ranges: 0 to 10.000 ppm methane operating time: > 12 hours without backlight and 20°C dimensions: 149 x 58 x 34 mm (plus 172 mm goose neck) weight: approx. 450 g explosion-proof instrument: sign: II 2G Ex ib d IIB T3 Gb BVS 05 ATEX E 010 X temperature range: -20°C < Ta < +50°C
每页条目
1 - 20 / 84