EDS2-V flow meter 1-42l/min 5%
新的
EDS2-V flow meter 1-42l/min 5%Digital flow meter to connect to smart memo. Measurement data are automatically transferred and used, for example, for the pressure drop test according to German DVGW guideline W 400-2. Can be used for the following drain volumes in water pressure tests (e.g. W 400-2/W 101): min. 32 ml max. 84 litres Sensor type: flow meter Measuring range: 1-42l/min. Accuracy: 5% of MW. Operating temperature: 0°C to +70 °C Max. pressure: 25 bar Connection: inlet nipple series 5020, outlet Geka coupling Instructions for use: For proper measurement results, the sensor must be rinsed with water before the test is carried out!
EDS2 automatic drain module
新的
EDS2 automatic drain moduleOptional module for the smart memo to automatically perform pressure drop tests and pressure reduction during water pressure tests. The EDS2 automatic drain is connected directly to the test head HANS with an integrated hose piece. On the outlet side, a suitable EDS2-V must be connected to the EDS2 automatic pressure release. The automatic pressure release only works in combination with an EDS2-V for digital recording of the water volume! The automatic drain is currently supported in the following processes: W 400-2: contraction procedure, accelerated standard procedure, standard procedure, infuence-minimized standard procedure W 101: contraction procedure, standard procedure EN 805: contraction procedure, standard procedure Mechanical connections: - hose connection with nipple series 5000 on the inlet side - on the outlet side coupling Series 5000 - bracket for fixing to the test stand pipe Electrical connections: - 1x socket B11 on the inlet side (power supply via smart memo) - on the outlet side, 3x connector B11 for direct connection of further EDS2 sensors (no additional T-pieces necessary) max. pressure 30 bar max. flow 75 liters/minute
Temperature sensor ground stake EDS2-T 0,1K
新的
Temperature sensor ground stake EDS2-T 0,1KMeasuring range: 0°C to 40 °C Measuring range resolution: up to 0.01 °C Accuracy: 0.1 °C Total length: 1.04 m Material: stainless steel
EDS2-V flow meter 4-160l/min 5%
新的
EDS2-V flow meter 4-160l/min 5%Digital flow meter to connect to smart memo. Measurement data are automatically transferred and used, for example, for the pressure drop test according to German DVGW guideline W 400-2. Can be used for the following discharge volumes in water pressure tests (e.g. W 400-2/W 101): min. 8 litres max. 320 litres Sensor type: flow meter Measuring range: 4-160l/min. Accuracy: 5% of MW. Operating temperature: 0°C to +70 °C Max. pressure: 25 bar Connection: inlet nipple series 5020, outlet Geka coupling Instructions for use: For proper measurement results, the sensor must be rinsed with water before the test is carried out!
Temperature sensor contact element EDS2-T 0,1K
新的
Temperature sensor contact element EDS2-T 0,1KMeasuring range: 0°C to 40 °C Measuring range resolution: up to 0.01 °C Accuracy: 0.1 °C Docking element with an elastic belt for fixing to the pipe, up to approx. OD 500. Material: synthetic material (housing), aluminum (contact face)
External pressure sensor EDS2-P 50 bar 0,1%
新的
External pressure sensor EDS2-P 50 bar 0,1%can be used on the measuring device via connection cable Sensor type: absolute pressure sensor Measuring range: 0 to 50 bar above atmospheric pressure Measuring accuracy: < 0.1% of final value Operating temperature: -20 °C to +70 °C Max. pressure: 70 bar Connection: external thread G 1/4 Suitable for pressure tests according to W 400-2 (08/2022) with high test pressure: STP > 21 bar
External pressure sensor EDS2-P 10 bar 0.1% DAkkS
External pressure sensor EDS2-P 10 bar 0.1% DAkkSincl. DAkkS calibration certificate (initial certification according to G 469) can be used on the measuring device via connection cable Sensor type: Absolute pressure sensor Measuring range: 0 to 10 bar above atmospheric pressure Measuring accuracy: < 0.1% of full scale Operating temperature: -20 °C to +70 °C Max. Pressure 15 bar Connection: external thread G 1/4".
Pressure sensor EDS2-P 25 bar 0,1%
Pressure sensor EDS2-P 25 bar 0,1%deployable to measurement device via connecting cable sensor type: absolute pressure sensor measurement range: 0 to 25 bar above atmospheric pressure measurement accuracy: < 0,1 % of full scale operating temperature: -20 °C bis +70 °C maximum pressure: 40 bar connection: external thread G 1/4"
Connecting cable B11 5m
Connecting cable B11 5mfor external digital sensors (EDS2), length: 5 m connection to smart memo
T-piece B11
T-piece B11T-connection piece B11 bayonet coupling 11 mm
Pressure Sensor EDS2-P 15bar 0,01% 0-40°C
Pressure Sensor EDS2-P 15bar 0,01% 0-40°Capplicable at the measuring device via connecting cable sensor type: absolute pressure sensor measurement range: 0 to 15 bar above atmospheric pressure measurement accuracy: < 0,02 % of full scale measurement precision: < 0,01% of full scale at 0-40°C resolution: 1 mbar operating temperature: -20 °C bis +70 °C maximum pressure: 50 bar connection: external thread G 1/4"
External pressure sensor EDS2-P 10 bar 0,1% 0-40 °C incl. DAkkS
External pressure sensor EDS2-P 10 bar 0,1% 0-40  °C incl. DAkkScan be used with the measuring device via connection cable incl. DAkkS calibration certificate (initial certification) Sensor type: absolute pressure sensor Measuring range: 0 to 10 bar above atmospheric pressure Measuring accuracy: < 0.1% of final value at 0 - 40°C Operating temperature: -20 °C to +70 °C Max. pressure 15 bar Connection: outer thread G 1/4"
Temperature sensor contact element EDS2-T 0,1K DAkkS
Temperature sensor contact element EDS2-T 0,1K DAkkS
including DAkkS calibration certificate Measuring range: 0°C to 40 °C Measuring range resolution: up to 0.01 °C Accuracy: 0.1 °C Docking element with an elastic belt for fixing to the pipe, up to approx. OD 500. Material: synthetic material (housing), aluminum (contact face)
Pressure sensor EDS2-P 10 bar 0,1%
Pressure sensor EDS2-P 10 bar 0,1%deployable to measurement device via connecting cable sensor type: absolute pressure sensor measurement range: 0 to 10 bar above atmospheric pressure measurement accuracy: < 0,1 % of full scale operating temperature: -20 °C to +70 °C maximum pressure: 15 bar connection: external thread G 1/4"
Temperature sensor ground stake EDS2-T Measuring range: -20°C to 70 °C
Temperature sensor ground stake EDS2-T
Measuring range: -20°C to 70 °CTemperature sensor ground stake EDS2-T Measuring range: -20°C to 70 °C Measuring range resolution: up to 0,01 °C Accuracy: 0,25 °C Total length: 1,04 m Material: stainless steel This sensor can be used for the measurement of temperatures for pressure tests according to W 400-2 and G 469 B3. He cannot get an initial certification according to G 469 C3 (high precision pressure test procedure).
Connecting cable B11 or extension cable B11, 1m
Connecting cable B11 or extension cable B11, 1mto connect external digital sensors (EDS2) with smart memo
Handheld sensor gas detection GasTest delta3
Handheld sensor gas detection GasTest delta3with integrated calibration data and vibration alarm deployable with every GasTest delta3
External pressure sensor EDS2-P 1,6bar 0,25%
External pressure sensor EDS2-P 1,6bar 0,25%Pressure sensor EDS2-P 1,6 bar 0,25% can be used on the measuring device via connecting cable sensor type: absolute pressure sensor measurement range: 0 to 1,6 bar above atmospheric pressure measurement accuracy: < 0,25 % FS for 0-400 mbar < 0,25 % FS for 0-1600 mbar operating temperature: -20 °C bis +70 °C maximum pressure: 2 bar connection: external thread G 1/4"
External pressure sensor EDS2-P 300 bar 0,05%
External pressure sensor EDS2-P 300 bar 0,05%applicable at the measuring device via connection cable Sensor type: absolute pressure sensor Measuring range: 0 to 300 bar above atmospheric pressure Measuring accuracy: < 0.05% of final value Operating temperature: -20 °C to +70 °C Max. pressure : 500 bar Connection : external thread G 1/4"
External pressure sensor 0 to 15 bar
External pressure sensor 0 to 15 barfor DruckTest memo type 2006/W400/NL Accuracy 0,02% Precision 0,01% Resolution 1mbar incl. connection cable incl. nipple series 2520 IW G1/4 incl. plastic case with foam insert