产品
设备技术 SAFE EthanTest
SAFE EthanTest - 481001
SAFE EthaneTest
SAFE EthaneTest
Analyser for easy differentiation between natural gas and biogas
- rugged complete system in a service box
- including test probe and test probe hose
- fully automatic sampling and analysis within five minutes
- documentation with the built-in printer
- data memory and infrared interface to transfer all measurements
to the PC
technical data:
- display: LCD graphic display 128 x 64 pixels, illuminable
- power supply: lead accumulator, integrated charging system with 12 V input
- operating time: depending on outside temperature, over 50 analyses
- analysise range: depending on the ethane concentration in natural gas
from approx. 1000 ppm to 100 Vol. % natural gas
- operating temperature: -10°C to +45°C
- dimensions: 350 x 300 x 150 mm
- weight: approx. 5600 g
说明
在燃气泄漏检测的实际操作中,准确有效的区分引起报警的气体是天然气还是生物气体
(沼气)是非常必要的。生物气体(沼气)常来源于下水道、污水井、化粪池、自来水井、电力暗
沟、电信管道、暗沟、检查井等,准确区分不同气体,可有效地避免检测失误,避免不必要的开
挖施工,降低运行成本。
气样中是否含有乙烷成份(C2H6),是区分天然
气和沼气的最有效的指标,因为乙烷仅存在于天然气
中。SAFE乙烷分析仪通过其内置的气象色谱分离柱,对
气样中的不同成份进行分离检测。较小的甲烷分子首先
被分离,如果气样中含有天然气,则其中所含有的乙烷
随后被分离。
利用气相色谱技术进行燃气成份界定已经面世多
年,但之前的操作相当复杂,只有经验非常丰富的人员
才可得出清晰的判断和结论。随着SAFE乙烷分析仪的
出现,这种要求结束了!
实际操作步骤
- 携带SAFE乙烷分析仪到现场
- 开启仪器,连接取样管
- 开始分析,得出结论并打印
- 检测结果同时存储于仪器记忆中
技术数据
显示 | LCD显示128 x 64 pixels,带背景灯 |
---|---|
电源 | 铅酸电池 |
运行时间 | 取决于环境温度以及连续分析次数 |
分析范围 | 取决于天然气中的乙烷浓度,约1,000 ppm 至100 vol.-%天然气 |
运行温度 | - 10 °C 至 + 45 °C |
数据处理 | 内置热敏打印机,检测数据自动存储 |
外形尺寸 | 350 x 300 x 150 mm |
重量 | 约 5,000 g |