产品
C3 Drainage Case - 222032
Pressure drop test system
according to DVGW G 469
system EWE
Pressure drop test case according to DVGW G 469 C3 - System type EWE
Scope of delivery:
- case for pressure drop test with different volume
- software for PC with USB connectiong cable
- connecting hose 4 m 1620 - 1620
- connecting adapter with nipple S 2520 for test head
- PTB calibration certificate (DAkkS)
Description
Features
- safe and simple physical principle
- 3 calibrated volumes integrated in the case
- clear monitoring and display of the valve circuits
Technical Data
Scope of delivery | Carrying case, connection adapter Minimess - nipple Series 25, Minimess hose 1620 4m, USB connection cable, CD with PC control software |
---|---|
Software | Associated PC-Software for operating systems Windows XP and higher |
Pressure connection type | Type Minimess Series 1620 |
Power supply | via USB connection |
Current consumption | less than 300 mA |
Pressure range | up to 25 bar |
Display | Control manometer and multicoloured LEDs |
Switchable volumes | 3 calibrated, switchable volumes with ca. 1 cm3, 10 cm3 and 100 cm3 volume (see calibration certificate) |
Operating temperature | -10 °C to +50 °C |
Dimensions | 350 mm x 300 mm x 150mm |
Weight | ca. 4,5 kg |